LB02A Multifunction Process calibrator is a max. 0.25% high precision process controlling signal calibration meter. It can be used as an mV mA frequency process calibrator and digital multimeter to output and measure 0-20mA, 0-10V, 0-5V, 24V, voltage current signal, type K, J, B, S, T, N, thermocouple signal, PT1000, PT100, CU500 RTD signal, 0-10KHz frequency signal, resistance signal output, curves signal output, etc. That LB02A process calibrator can be used as an mV mA calibrator, current loop calibrator, frequency calibrator, temperature calibrator, digital multimeter, etc. LB02A (* No MODBUS, Hart functions) Main Features 1. Measurement ranges: 0-10KHz frequency, 0-30V, 0-150mV, 0-999.9Ω, standard R, E, S, K, J, B, T, N type thermocouple, PT100, CU50, 24V, 0-24mA, etc. 2. High-resolution color LCD, have backlight for different lighting conditions, large screen clear display. 3. Fast response, no delay in signal source simulation and signal testing or measurement. 4. Have battery charging and a status bar. Users can check the battery status quickly. 5. Can be used as a signal generator, frequency calibrator, multifunction process calibrator, and digital multimeter. 6. Have description in Hz, V, mV, mA, RTD, TC, Step, and Ω keys. It enables the user to operate it efficiently. 7. Frequency signal, DC voltage, mV small signal, resistance signal, DC, thermocouple, RTD thermal resistance signal output, and measurement equals a process calibrator and digital multimeter. 8. AD, DA, reference voltage, and OP circuits are used to ensure all high accuracy, high performance, and high stability 9. Using 4 units of PPTC and a quick-break fuse to protect the instrument from damage by high voltage. LB02A Process Calibrator is the upgraded version of LB02 Process Calibrator, and LB02A Accuracy is much higher. The output and measuring precision of LB02A are the same as that of the LB02 Process Calibrator. Due to lighting differences, the LCD screen picture shown is not clear. * Ohm, RTD output & measurement: Lead resistance error is not included in the accuracy. * Thermocouple output & measurement: Cold junction error is not included in the accuracy. * LB02A Process calibrator has No MODBUS, HART function (If need MODBUS, Hart function, recommend use: LB06 Process Calibrator ) *This LB02A multifunction process calibrator covers almost all the functions of temperature calibrator, frequency calibrator, mV mA loop calibrator, etc. Packing contents: 1 Unit x New LB02A Portable Precision Process Calibrator (No MODBUS, Hart Functions) 1 Set x High safety standards alligator testing clips 1 Unit x High quality 2A USB Cable for Battery Re-charge 1 Unit x High-quality meter bag 1 Set x Professional Easy-to-understand User Manual